Until they can do that, they dont get a meter. This just means that when the new or existing master meter needs to be tested, the operator can either use an existing, on-site storage tank or any large tanker (fire truck if the capacity is large enough) with a known capacity to verify the meter accuracy. <9D> <9D> <2022> %%EOF /CIDSystemInfo 1.1 Land Use Assumptions and Projected Population The BPSUD water system operates as 4 independent pressure planes, which requires that each pressure plane be analyzed as a stand-alone system. This eliminates the need for a system to conduct manual drive-bys and allows all meters to be read from the whole system in a matter of minutes from the office. Furthermore, Section 290.44(d)(4) states that, each community public water system shall provide accurate metering devices at each residential, commercial, or industrial service connection for the accumulation of water usage data. Section 290.38 defines a connection as a single-family residential unit or each commercial or industrial establishment to which drinking water is supplied from the system. Including this language in a notification letter to all utility customers will help explain why the system is requiring a change for existing multiple connections. %PDF-1.7 endcmap Email: [email protected], Water University/Utility Management Certification, TCEQ Requirement All Occupational Licensing, Wastewater Technical Assistance & Training Program, Click Here to Return to the Ask Larry Archives Homepage, Metering & One Meter per Residence Rules (Ask Larry). <9F> <9F> <0178> Ive also not heard of a system providing a water commercial permit. Use of the word commercial by a water system is typically a reference indicating that it is non-standard service and not a regular residential service location. Q: A member of our WSC has two water meters on his property. <09> <0A> <0009> 374 0 obj <00> "Equivalent residential units" or "ERU" is a unit of measurement based upon a standard single-family residential home used to establish rates, fees and charges and volume capacity limits. If a member purchases land other than where the original meter was installed, according to the TRWA Sample Tariff language, they have to transfer the membership to the new property owner and leave the meter in place. The defined area is depicted in Appendix 1. Check to see if this reference is included anywhere and if not, call the supplier or the manufacturer for a copy to keep in your files in case the question comes up in the future. One of the main reasons for a turbine or propeller master meter to register incorrectly is improper piping configurations from the well to and past the meter location. Example: A 20-space trailer park with a 2-inch meter has been evaluated by some TCEQ inspectors to be the actual number of trailer spaces available. Private or domestic wells can be used for a variety purposes, such as irrigation, drinking water and industrial uses. X1'H`7g3a*|f{h00eiF`
BVb`+c0 z^
With regard to your 1.5 inch line, please note that the TCEQ Chapter 290 Rules state that a 2 inch main line size is the minimum to be installed on any public water system. end %PDF-1.3
%
endstream
endobj
340 0 obj
<. Austin, TX 78701
endstream
endobj
5 0 obj<>/Width 2550/Height 3300/BitsPerComponent 1/ColorSpace/DeviceGray/Type/XObject/Name/background_2/Subtype/Image>>stream
A new membership fee should be required for each new meter. Again, this is an insurance issue to address with your insurance carrier. Extension of pipe(s) to transfer utility service from one property to another, to share, resell, or submeter water to any other persons, dwellings, businesses, or property, etc., is prohibited. <9E> <9E> <017E> 69 0 obj<>
endobj
The quadplexes were built in 2006 and are not located within the boundaries of a city. endcodespacerange R02 - Single Family House (larger than 5/8 " meter). <8D> <8D> <2022> I told her that was incorrect and that I would mail her the documentation to prove it. The customer says there is a gate at the back of his property (more than 500 feet away). <96> <97> <2013> Other systems are installing AMR Meters for the first time, installing AMR Meters in high density or high-traffic areas or upgrading to AMI meters. >> def The member wants to know if a neighbor can hook up to the meter and if so, under what circumstances. There may be limitations that prevent using the meter when there is an outside water ban or other drought measures are in place. /Supplement 0 <91> <92> <2018> Q: What can you tell me about the new "electronic read" meters on the market today? All usage rates per thousand gallons should be the same across all classes of ratepayers, although conservation rates, designed to encourage efficient and non-wasteful water use practices by customers, can assess higher usage rates per thousand gallons for customers using more than a specified amount each month. This includes design, review and approval of all plans and all on-site and off-site service facilities by the corporations engineer and compliance with any applicable municipal or other governmental codes and specifications. Hopefully the two figures are the same or within a reasonable margin of error. Due to an expansion, the two split and are now serviced by the same meter. These items became assets and therefore had to be maintained and upgraded at the expense of the water system. If your board would like for one of TRWAs staff to attend a meeting to do some rate training, please contact our office. Based on my experience, a great number of systems opt to have a single meter properly sized to meet the service needs requested by the owner instead of having multiple smaller master meters or even individual meters for each apartment. <88> <88> <02C6> 0000002796 00000 n
CMapName currentdict /CMap defineresource pop Using the formula 3.14 X Radius X Radius X Height X 7.48 (gallons per cubic feet) you can calculate the number of gallons of water added to the storage tank. xc```a``A2@\(}drBf 0000036396 00000 n A: This is a common problem for older systems as they try to come into compliance with newer rules. For example, in Section E, Members Responsibility: d. Therefore, all water usage registering upon and/or damages occurring to the metering equipment owned and maintained by the Corporation shall be subject to charges as determined by the Corporations Tariff as amended from time to time by the Board of Directors. The capacity is being used either way, and these new meters and customers are utilizing their share of the systems resources. Q: We have several members who have second living residences at their home, but only one meter. <9E> <9E> <017E> Ask Larry Archives: Metering and One Meter per Residence Rules. Others were due to leaks grounding out meters. This only works for meter reading and does not solve the issue of access for repairs and emergencies. |pz~0u]MbHw{B|%r4ln'Ur]af2Ia0 fkF0S;@G bYH(?I
The two businesses had been in a partnership in the past under one roof. Wouldnt it make sense for the owner to have to pay the cost of extending the line(s) out to those structures? <00> TCEQ staff at the time said it would be ok for a system to remove dormant or vacant taps even down to the water main, but the system could not assess any future applicant a new front-end contribution or equity buy-in fee, equipment costs to replace the assets being removed and possibly another membership fee if the system used non-refundable membership fees at those locations where these taps had been removed. Then a straight run of pipe at least three times the diameter of the pipe after the meter. This letter should outline the PUC requirements for an accurate metering of water per connection. A: The TRWA Sample Tariff states that a meter is to be set on the property designed to receive service and the owner of the property has to be the member of the corporation. 69 12
The TCEQ rules dont necessarily state that the calibration must take place upon installation but the clock has to start somewhere and the safe option is to calibrate the meter yourself or secure a certificate of accuracy from the meter company. It is up to each customer to determine whether they must register as a business with the state or not. {Y 9w,r,
6Q@4Og)nF9c"|A""?__ovt^o_dM`L2,s54#Pj0 /Ordering (UCS) A standard single-family home is considered a standard ERU with other uses measured against this baseline. 0000001247 00000 n If your systems tariff contains the same language as TRWAs sample tariff, failure to remedy this hazardous condition is subject to disconnection without notice, and ultimately cancellation of membership due to policy non-compliance in accordance with Section E if the issue is not remedied. Whatever the reason for requesting a second or third meter, they get irritated when they are denied the other meter (or told they will have to pay the cost of paralleling the line) while the person behind their property is enjoying a meter on their property. Published in July/August 2020 (Issue 4 of Quench). endcodespacerange <95> <95> <2022> u6hhOk\GhExG-GMYsjYQC\+8*w}ap|B"[C>B\`y[%s*H X[S.3Sj_S\Z'e5TsAd D>~/mOJ>hnm={^hcb(T-C2bm4M"#Zg7;qqFY(kG1jCA XZ0SRpnNN7aQR7.LX*VAT\pPx(aPs
What should we do with these boxes? startxref 10. All new customers or applicants for water service use some of the systems existing facilities and capacity that was already in place things like pipe lines, tanks, wells, pumps and so on. TRWA recommends that systems stop floating memberships and meters from one property to another because of the confusion it creates. /Ordering (UCS) <0D> <0D> <000D> Define Equivalent Single-Family Connection. Further, in the past we have seen many TCEQ investigators count dead taps into the systems overall capacity requirements using the assumption that at any time in the future the system would still be responsible for supplying not only the active connections but previously existing connections also. Even if the customer would only need standard service, TRWAs Sample Tariff includes the requirement that the property of the applicant/ member shall be inspected to ensure compliance with state required Minimum Acceptable Operating Practices for Public Drinking Water Systems as promulgated by the Texas Commission on Environmental Quality (TCEQ) or successor agency. A: Yes, under Chapter 13 of the Texas Water Code you must provide service to the applicant if the location of the request for service lies within your certificated service area and your utility is privately owned or a nonprofit water supply corporation. In the case of choosing a meter read system, we suggest that the meter supplier provide you with a list of systems that uses their meters so your system can check out the pros and cons with other systems that are using the meters. However, if your homeowner needs a 1" or larger meter, then the requirements for non-standard service as outlined in Section F. of the TRWA Sample Tariff would apply, including an engineering study for each oversized meter. <9C> <9C> <0153> <84> <84> <201E> :SYA"e2=pmn':"^Ptvop?L`EekP)H:^OK)XNI Do you have a source for best practices when planning to deal with this issue? <91> <92> <2018> %PDF-1.5
%
What a system considers to be reasonable access may vary. endbfrange endcmap That availability to use that capacity should be paid for, but not by tacking the costs onto existing customers. The Members use of the Corporations curb stop or other similar valve for such purposes is prohibited. H|T0WQNd(>3IQb= A: This is definitely not a new question - many systems have faced this situation over the years. <85> <85> <2026> This is referred to in Section C under the definition of member and proof of ownership, and again in Section E under Rules and Regulations. 1. When setting these new meters, it is important to remember that if the property is subdivided in the future, each meter should be on the property with the residence or structure to be served. <7F> <7F> <2022> As a general rule, the only difference should be in base rates based on size of meter as indicated in the TRWA Sample Tariff. 0000005203 00000 n
endstream
endobj
1 0 obj<>
endobj
2 0 obj<>/XObject<>/ProcSet 79 0 R>>
endobj
3 0 obj<>stream
If not then the meter accuracy is over or under by that difference since the tank is a definite volume (provided the above calculation and tank dimensions were accurate). 0000000536 00000 n
<84> <84> <201E> The original member will pay all costs associated with a new meter installation as if they were a new customer, since they are a new customer at this new location. An eight-inch (8") water main will generally be required to distribute water and provide fire protection within the multi-family district provided that the water main does not exceed 600 feet in length or serve more than two Requiring employees to climb ladders to get over fences or traverse 500 feet of property may not be reasonable access for your system and could be considered denial of access. As an example, the number of service connections in an apartment complex would be equal to the number of individual apartment units. The TRWA Sample Tariff addresses this issue and follows the Public Utility Commission (PUC) Chapter 24 rules about the systems ability to access a meter for repairs and normal service. <99> <99> <2122> <<9e8032b06c2c514a87349e8822134d26>]>>
A: In the TRWA Sample Tariff, as well as in the USDA-RD Service Application and Agreement Form, it states that a meter shall be installed on a property to serve that single property and water cannot be diverted to another property. <82> <82> <201A> <98> <98> <02DC> <00> My question is what is considered access? Where to live in Delft Wedged between The Hague and Rotterdam, Delft is a beautiful historical town that attracts those seeking a quieter lifestyle with good city connections.
-tjOXWIR-9L#|qAH)=ya[AXO>_u 9U]](M:?`^V a/X`jsV60;aC}18Y_{/c%nmVlf.0FVL Section 24.89(a)(1) of the PUC's rules states that, all charges for water service shall be based on meter measurements, except where otherwise authorized by the utilitys approved tariff.. A: This is one of those situations where a little extra effort by the system up front can save them substantial headaches and costs down the road. The rules go on to state that once a system begins to use some of that extra capacity, they need to begin designing specific improvements which will replace this used capacity. endcmap Next, the utility should contact the systems engineer to obtain a study showing how the number and location of the different dwellings are situated on the tract of land. We have been mostly going by the word of individual landowners, which has recently resulted in us finding out that some of our meters were not correctly located. All public water systems that hold CCNs (or are required to hold CCNs) must plan upgrades to the system when a facility, including distribution lines, reaches 85 percent of total capacity so that the improvement or upgrade is imminent or already in place once the facility item under consideration reaches 100 percent capacity. ]BA Y,bps`>x/@HnqXNZ1yek5Fq8:^bV_W
=.*'&0Y5E4oUpcbT6P,SkV/ lliF7LEM]AgDtC,a]oaF![Oi0
qy}>XPN&:VYCp>F0 "
<00A0> 0000000825 00000 n
<8C> <8C> <0152> All the meters or at least the material data sheets should state that the materials used to manufacture the meters meet NSF 61. <81> <81> <2022> Some of this cost will be paid by these new customers once they start paying their monthly water bill, but the previous customers not only have been paying for what it costs for them to receive water delivered to their homes, they have also been paying a bit extra toward the complete debt-service for all existing capacity. In fact, there are laws about meter tampering, damage and diversion if a person is caught or found guilty of messing with a utilitys meters. There are many points that need to be addressed before agreeing to this offer. By doing this, when they get a few more meters, they can begin replacing the meter tops with these newer AMI tops. If they want service at a new location, they must purchase another membership and meter tap, and comply with all the new service application procedures. Service will be restored when a CSI confirms no health hazard exists, the health hazard has been removed or repaired, or the health hazard has been isolated from the corporations water system. A: This is an issue weve been talking to TCEQ about as far back as 2004. H_w"'i.wF%P)O The closest thing we have to a bottom line here is that a system can remove the meter, but they still need to maintain capacity at that same location in case a future applicant wants to re-install another water meter there. 1 year ago. Q: A current member of our WSC has asked for a second meter on their property. 67.016(d) provides that a corporation may make water or sewer service conditional on ownership of the real estate designated to receive service and from which the membership or other right of participation arises. Subsection (e) authorizes a corporation to cancel a persons membership if he fails to meet a condition of service prescribed by the corporation.